Everything Totally Explained


Ask & we'll explain, totally!
Parts-per notation
Totally Explained


  NEW! All the latest news in the worlds of computer gaming, entertainment, the environment,  
finance, health, politics, science, stocks & shares, technology and much, much, more.  


View this entry using RSS

Everything about Part Per Million totally explained

"Parts-per" notation is used, especially in science and engineering, to denote relative proportions in measured quantities; particularly in low-value (high-ratio) proportions at the parts-per-million (ppm), parts-per-billion (ppb), and parts-per-trillion (ppt) level. Since parts-per notations are quantity-per-quantity measures, they're known as dimensionless quantities; that is, they're pure numbers with no associated units of measurement. In regular prose, parts-per notations generally take the literal "parts per" meaning of a comparative ratio. However, in mathematical expressions, parts-per notations function as coefficients with values less than 1.

Overview

Parts-per notation is often used in the measure of dilutions (concentrations) in chemistry; for instance, for measuring the relative abundance of dissolved minerals or pollutants in water. The expression “1 ppm” means a given property exists at a relative proportion of one part per million parts examined, as would occur if a water-borne pollutant was present at a concentration of one-millionth of a gram per gram of sample solution.
   Similarly, parts-per notation is used also in physics and engineering to express the value of various proportional phenomena. For instance, a special metal alloy might expand 1.2 micrometers per meter of length for every degree Celsius and this would be expressed as “α = 1.2 ppm/°C.” Parts-per notation is also employed to denote the change, stability, or uncertainty in measurements. For instance, the accuracy of land-survey distance measurements when using a laser rangefinder might be 1 mm per km of distance; this could be expressed as "Accuracy = 1 ppm".
   The above parts-per notations are all dimensionless quantities; that is, in mathematical expressions, the units of measurement always cancel in fractions like “2 nanometers per meter” (2 nm/m = 2 nano = 2 × 10–9 = 2 ppb = 2 × 0.000000001) so the quotients are pure-number coefficients with values less than 1. When parts-per notations, including the percent symbol (%), are used in regular prose (as opposed to mathematical expressions), they're still pure-number dimensionless quantities, however, they generally take the literal "parts per" meaning of a comparative ratio (for example, "2 ppb" would generally be interpreted as "two parts in a billion parts").
   Note that although the International Bureau of Weights and Measures (an international standards organization known also by its French-language initials BIPM) recognizes the use of parts-per notation, it isn't formally part of the International System of Units (SI). Also, because the named numbers starting with a "billion" have different values in different countries, the BIPM suggests avoiding the use of "ppb" and "ppt" to prevent misunderstanding. Nevertheless, parts-per notation, particularly the expression "ppm", remains widely used in technical disciplines because of its convenience in denoting dimensionless quantities. See Alternatives to parts-per notation, below.

Parts-per expressions

  • One part per hundred: Should be represented by the percent (%) symbol and denotes one part per 100 parts, one part in 102, and a value of 1 × 10–2. This is equivalent to one drop of water diluted into 5 milliliters (one spoon-full) or one second of time in 1⅔ minutes.
  • One part per thousand: Should be spelled out in full and should avoid the use the “ppt” abbreviation, which is usually understood to represent “parts per trillion”. It may also be denoted by the permille (‰) symbol. Note however, that specific disciplines such as the analysis of ocean water salt concentration and educational exercises occasionally use the “ppt” abbreviation. “One part per thousand” denotes one part per 1000 parts, one part in 103, and a value of 1 × 10–3. This is equivalent to one drop of water diluted into 50 milliliters (ten spoon-fulls), or one second of time in 16⅔ minutes.
  • One part per ten thousand: Is denoted by the permyriad (‱) symbol. It is used almost exclusively in finance, where it's known as the basis point and is typically used to denote fractional changes in percentages. For instance, a change in an interest rate from 5.15% to 5.35% would be denoted as a change of 20 basis points or 20 ‱.
Although rarely used in science (ppm is typically used instead), one permyriad has an unambiguous value of one part per 10,000 parts, one part in 104, and a value of 1 × 10–4. This is equivalent to one drop of water diluted into half a liter, or one second of time in approximately 2¾ hours.
  • One part per million (ppm): Denotes one part per 1,000,000 parts, one part in 106, and a value of 1 × 10–6. This is equivalent to one drop of water diluted into 50 liters (roughly the fuel tank capacity of a compact car), or one second of time in approximately 11½ days.
  • One part per billion (ppb): Denotes one part per 1,000,000,000 parts, one part in 109, and a value of 1 × 10–9. This is equivalent to 1 drop of water diluted into 250 chemical drums (50 m³), or one second of time in approximately 31.7 years.
  • One part per trillion (ppt): Denotes one part per 1,000,000,000,000 parts, one part in 1012, and a value of 1 × 10–12. This is equivalent to 1 drop of water diluted into 20, two-meter-deep Olympic-size swimming pools (50,000 m³), or one second of time in approximately 31,700 years.
  • One part per quadrillion (ppq): Denotes one part per 1,000,000,000,000,000 parts, one part in 1015, and a value of 1 × 10–15. This is equivalent to 1 drop of water diluted into a cube of water measuring approximately 368 meters on a side (fifty million cubic meters, which is a cube about as tall as the roof of the Empire State Building), or one second of time in approximately 31.7 million years. Although relatively uncommon in analytic chemistry, measurements at the ppq level are performed.

    Alternatives to parts-per notation

    SI-compliant expressions

    In the English language, named numbers have a consistent meaning only up to "million". Starting with "billion", there are two numbering conventions: the "long" and "short" scales, and "billion" can mean either 109 or 1012.
       Although the BIPM recognizes the use of "parts per million" (ppm) to represent dimensionless quantities, it cautions that due to the above-mentioned language differences and also because "ppt" occasionally means "parts per thousand", both "ppb" and "ppt" should be avoided to prevent misunderstanding. Note however, that the NIST’s stated premiss for its position is only partially true; "million" has only one meaning in all languages. Note too, that although "percent" (%) isn't formally part of the SI, both the BIPM and the ISO, take the position that "in mathematical expressions, the internationally recognized symbol % (percent) may be used with the SI to represent the number 0.01" for dimensionless quantities. Because parts-per notation generally has a well-understood meaning in modern, English-speaking scientific circles, and because its use simplifies the expression of dimensionless quantities, parts-per notation remains widely used in technical disciplines today. Expressions that the BIPM doesn't explicitly recognize as being suitable for denoting dimensionless quantities with the SI are shown in maroon text in the chart below.
    NOTATIONS FOR DIMENSIONLESS QUANTITIES
    Measure SI
    units
    Named
    parts-per ratio
    Parts-per
    abbreviation
    or symbol
    Value in
    scientific
    notation
    A strain of… 2 cm/m 2 parts per hundred     2% 2 × 10–2
    A sensitivity of… 2 mV/V 2 parts per thousand 2 ‰ 2 × 10–3
    A sensitivity of… 0.2 mV/V 2 parts per ten thousand 2 ‱ 2 × 10–4
    A sensitivity of… 2 µV/V 2 parts per million 2 ppm 2 × 10–6
    A sensitivity of… 2 nV/V 2 parts per billion 2 ppb 2 × 10–9
    A sensitivity of… 2 pV/V 2 parts per trillion 2 ppt 2 × 10–12
    A mass concentration of… 2 mg/kg 2 parts per million 2 ppm 2 × 10–6
    A mass concentration of… 2 µg/kg 2 parts per billion 2 ppb 2 × 10–9
    A mass concentration of… 2 ng/kg 2 parts per trillion 2 ppt 2 × 10–12
    A mass concentration of… 2 pg/kg 2 parts per quadrillion 2 ppq 2 × 10–15
    A stability of… 1 (µA/A)/min. 1 part per million per min. 1 ppm/min. 1 × 10–6/min.
    A change of… 5 nΩ/Ω 5 parts per billion 5 ppb 5 × 10–9
    An uncertainty of… 9 µg/kg 9 parts per billion 9 ppb 9 × 10–9
    A shift of… 1 nm/m 1 part per billion 1 ppb 1 × 10–9
    A strain of… 1 µm/m 1 part per million 1 ppm 1 × 10–6
    A temperature coefficient of… 0.3 (µHz/Hz)/°C 0.3 part per million per °C 0.3 ppm/°C 0.3 × 10–6/°C
    A frequency change of… 0.35 × 10–9 ƒ 0.35 part per billion 0.35 ppb 0.35 × 10–9
    Note that the notations in the “SI units” column above are all dimensionless quantities; that is, the units of measurement cancel in expressions like “1 nm/m” (1 nm/m = 1 nano = 1 × 10–9) so the quotients are pure-number coefficients with values less than 1.

    Uno

    Because of the cumbersome nature of expressing certain dimensionless quantities per SI guidelines, the International Union of Pure and Applied Physics (IUPAP) in 1999 proposed the adoption of the special name “uno” (symbol: U) to represent the number 1 in dimensionless quantities.
       Common parts-per notations in terms of the uno are given in the table below.
    IUPAP’S “UNO” PROPOSAL
    Coefficient Parts-
    per
    example
    Uno
    equiv.
    Symbol
    form
    Value of
    quantity
    10–2 2% 2 centiuno 2 cU 2 × 10–2
    10–3 2 ‰ 2 milliuno 2 mU 2 × 10–3
    10–6 2 ppm 2 microuno 2 µU 2 × 10–6
    10–9 2 ppb 2 nanouno 2 nU 2 × 10–9
    10–12 2 ppt 2 picouno 2 pU 2 × 10–12
    In 2004, a report to the International Committee for Weights and Measures (known also by its French-language initials CIPM) stated that response to the proposal of the uno “had been almost entirely negative” and the principal proponent “recommended dropping the idea.” To date, the uno hasn't been adopted by any standards organization and it appears unlikely it'll ever become an officially sanctioned way to express low-value (high-ratio) dimensionless quantities. The proposal was instructive, however, as to the perceived shortcomings of the current options for denoting dimensionless quantities.

    Improper applications of parts-per notation

    Parts-per notation may properly be used only to express true dimensionless quantities; that is, the units of measurement must cancel in expressions like “1 mg/kg” so that the quotients are pure numbers with values less than 1. Mixed-unit quantities such as “a radon concentration of 15 pCi/L” are not dimensionless quantities and may not be expressed using any form of parts-per notation, such as “15 ppt”. Other examples of measures that are not dimensionless quantities are as follows:
  • Particulate matter in the air: 50 µg/m³  but not:  50 ppm
  • A stepper motor/gear system that produces a motion of 1 µm/pulse  but not:  1 ppm
  • Mercury vapor concentration in air: 0.6 ng/L  but not:  0.6 ppt Note however, that it isn't uncommon to express aqueous concentrations—particularly in drinking-water reports intended for the general public—using parts-per notation (2.1 ppm, 0.8 ppb, etc.) and further, for those reports to state that the notations denote milligrams per liter or micrograms per liter. Whereas “2.1 mg/L” is technically not a dimensionless quantity on the face of it, it's well understood in scientific circles that one liter of water has a mass of one kilogram and that “2.1 mg/kg” (2.1 ppm) is the true measure. The goal in all technical writing (including drinking-water reports for the general public) is to clearly communicate to the intended audience with minimal confusion. Drinking water is intuitively a volumetric quantity in the public’s mind so measures of contamination expressed on a per-liter basis are considered to be easier to grasp.

    Convertibility to other units of measurement

    Parts-per notations may be expressed in terms of any unit of the same measure. For instance, the coefficient of thermal expansion of a certain brass alloy, α = 18.7 ppm/°C, may be expressed as 18.7 (µm/m)/°C, or as 18.7 (µin/in)/°C; the numeric value representing a relative proportion doesn’t change with the adoption of a different unit of measure. Similarly, a metering pump that injects a trace chemical into the main process line at the proportional flow rate Qp = 125 ppm, is doing so at a rate that may be expressed in a variety of volumetric units, including 125 µL/L, 125 µgal/gal, 125 µ(m³)/m³, etc.

    Further Information

    Get more info on 'Part Per Million'.


    External Link Exchanges

    Do you know how hard it is to get a link from a large encyclopaedia? Well we're different and will prove it. To get a link from us just add the following HTML to your site on a relevant page:

      <a href="http://parts-per_notation.totallyexplained.com">Parts-per notation Totally Explained</a>

    Then simply click through this link from your web page. Our crawlers will verify your link, extract the title of your web page and instantly add a link back to it. If you like you can remove the words Totally Explained and embed the link in article text.
       As long as your link remains in place, we'll keep our link to you right here. Please play fair - our crawlers are watching. Your site must be closely related to this one's topic. Any kind of spamming, dubious practises or removing the link will result in your link from us being dropped and, potentially, your whole site being banned.



  • Copyright © 2007-8 totallyexplained.com | Licensed under the GNU Free Documentation License | Site Map
    This article contains text from the Wikipedia article Parts-per notation (History) and is released under the GFDL | RSS Version